Durability
Actuation cycles: 500 minimum
Current Carrying Capacity
2.8 Amps Max.
Probe Contact Force
18 g (per position)
Probe Contact Resistance
80 mOhms
Return Loss*
Differential Single-Ended
-10db @ 2.6 GHz -10db @ 8.0 GHz
-15db @ 1.3 GHz -15db @ 3.5 GHz
Insertion Loss*
Differential Single-Ended
-0.6db @ 2.6 GHz -2.1db @ 8.0 GHz
-0.2db @ 1.3 GHz -0.9db @ 3.5 GHz
*Complete SI Simulation Report Available